Home / Products / Molecular Sieve / CMS-260 Carbon Molecular Sieve

MOLECULAR SIEVE

CMS-260 Carbon Molecular Sieve

CMS-260 is a non-polar carbon adsorbent for separating nitrogen from air by pressure swing adsorption. Haina describes this grade as a material for nitrogen-enriched gas production with high oxygen-adsorption capacity.

ModelCMS-260
Diameter1.0–1.3 mm
Bulk Density650–670 kg/m³
Standard Packaging20, 40 or 137 kg/drum

Product Overview

The original page highlights nitrogen-generation efficiency and low air consumption, particularly in the 99.5% to 99.9% purity range. Its performance table provides additional purity points at the stated test pressure.

Applications

Haina lists large-scale air-separation nitrogen equipment and uses in coal mining, shipping, and petroleum storage and transport. Match the grade to the required purity and actual PSA conditions.

Technical Data

Physical Properties

Item CMS-260 Carbon Molecular Sieve Specifications
Diameter1.0-1.3mm
Bulk Density650-670Kg/m³
Particle Strength≥85N
Attrition Resistance≤1%
Moisture Content≤0.5%
Standard Packaging20 kg/drum, 40 kg/drum, 137 kg/drum

Nitrogen Generation Performance

Adsorption PressureNitrogen Purity (%)Nitrogen Yield (L/kg·h)Air-to-Nitrogen Ratio
0.7MPa98 3651:2.7
99315 1:2.8
99.5 265 1:3.2
99.9 1911:4
99.99 119 1:5.2

Published test conditions: adsorption pressure 0.7 MPa; adsorption time 42–50 seconds; pressure equalization 1–2 seconds. Review the purity, yield and air-demand values at the same operating point.

PSA Nitrogen Separation

Carbon adsorbent developed for the separation of nitrogen from air.

Published Performance

Compare nitrogen yield and air demand at the specified purity points.

Industrial Supply

Haina lists several drum sizes for this grade.

Storage & Selection

What information is needed to select CMS-260?

Please provide the feed-gas composition, desired product purity, required flow rate, operating pressure and temperature, plus the equipment configuration and cycle. For an existing system, include its current material grade and operating results. These details help Haina discuss a grade under comparable conditions.

How should I compare product specifications?

Compare values at the same test conditions and purity target. Particle size, bulk density and mechanical properties also matter to the vessel and process. The data on this page are a selection reference; request the current specification and confirm the relevant operating point before ordering.

How should unopened and unused material be stored?

Keep containers tightly sealed and dry. Prepare the equipment before opening a package, minimize exposure to humid air, and promptly reseal any unused material. Follow the product-specific storage instructions supplied with the order.

What should be checked before changing the adsorbent?

Identify the cause of the performance change first. Review feed pretreatment, moisture and oil carryover, filtration, pressure stability and the equipment cycle. Share the operating history with Haina so material selection can be discussed together with the condition of the system.

Does adding more CMS always improve nitrogen production?

No. Bed quantity must match vessel design, packing density, gas distribution and the PSA cycle. Uneven loading or localized high-velocity flow can reduce performance and damage particles. Follow the equipment supplier’s approved filling and commissioning procedure.

Related Products

PRODUCT & APPLICATION SUPPORT

Discuss the Right Material with Haina

Share your target gas, purity, flow and operating conditions. Our team can help you explore the relevant product range and specifications.

matt@cmsieve.com   ·   0086-18086046920